So total 2250 watts. I do. £ 5. Apple Pay accepted in store. PayPal accepted online. 433. Then I plan on running the cable down to the shed and in the shed wiring it to a garage consumer unit. Hence you are allowed one socket as a spur (as can't won't overload the ring with one 13a socket) from the ring but not multiple sockets, which need a fcu to protect the ring from possible overload. 5 or 2. com. With Flex Outlet. Wellwisher said: ↑. I’m not sure anything exists. Modern and intuitive design. 666. It was established in 1935 as Shell Employees Federal Credit Union, and now serves more than 30,000 members with more than $524 million in assets. Hi all looking for some help please… I am in the process of converting my garage in to a room. Apple Pay accepted in store. Supplied with Replaceable 13A Fuse. The UK’s leading retailer of trade tools and hardware. 4/5. Membership Eligibility. After looking at the switch wiring, it looks like it is a double pole switch with a load and supply. Of Poles Profile Type Switched or Unswitched Sort By: Results per page: 20 MK Logic Plus 13A Switched Fused Spur &. However, this is frowned upon as poor practice. I assumed (maybe incorrectly) that what was required above would have been fed off the FCU load as is the cooker hood, so when the FCU switch would be off it would in turn also isolate these new sockets. Terminals accept 3 x 2. Just run a twin and earth from the supply side of the existing fcu to the new ones supply side ,and connect both lights to its load side. Their initial thought was to cut the plug off this muti-way socket, and replace the current wall socket with a fused switch such as this: And wire the multiway adaptor into the back of this socket. Screwfix Community Forum. 5mm T&E to run 1 x outside weatherproof RCD protected Double socket. Order British General Nexus Metal 13A Switched Fused Spur Brushed Steel at Screwfix. Order MK Metal-Clad Plus 13A Unswitched Metal Clad Fused Spur with Neon with White Inserts at Screwfix. com. Buy any 10+ Save 10% - View Offer. Wiring electric hob diagram / installing a indesit ceramic hob diy home. 30 day money back guarantee. Flex Outlet. continuing in 2. And as in te original query - a plug on a cooker hood. com. Home Forums > Screwfix Community Forum > Electricians' Talk > Garage Feed From A 13 A FCU? Discussion in 'Electricians' Talk' started by scrumpy, Jan 19, 2007. com. ie. They even refer to switches as plugs and plugs as switches, sockets as plugs, etc etc. We identify you as the true “owner” of your account. Order 13A Switched Metal Clad Fused Spur & Flex Outlet with White Inserts at Screwfix. This means one has to wire a plug and cable. Don't know why there is a switch on the incoming feed, it is not necessary. I have had an electrician install a spurred FCU in the loft in preparation for a boiler to be. Bob Rathbone, Jul 18, 2018. Just about to change the Fused Connection Unit for a extractor fan and noticed the FCU is missing the earth cable. Screwfix Direct DIY, Paint Supplies: Shop Online at Screwfix Direct Home Improvement for UK Paint Supplies. 5mm to spur of a ring main that is protected by a 32amp breaker. PAGE 1 OF 7. May be better if you got an electrician to advise. Check the Fuse in the FCU. TM11 likes this. Heavy duty, metal-clad moulded safety RCD protected fused connection unit that protects against the risk of a fatal shock. Electrican has done the following, but isn't this. Without RCD. Sanitary Fixings Kits. . Delivery 7 days a week. 60 days free credit available. FREE next day delivery available, free collection in 1 minute. Membership is open to the family of existing. com. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. The problem is when I switch on the sheds fcu it trips the rcbo at the CU, however when i reset it all is fine and I can use the shed, it also trips when I switch off the sheds fcu. 30 day money back guarantee. FlyByNight, Jun 29, 2021. You are looking for a device that provides overload protection and earth leakage protection. - - - - Call 24/7 on: 03330 112 112 Call 24/7: 03330 112 112 Shop by. FREE next day delivery available, free collection in 1 minute. com. 89Inc Vat. PayPal accepted online. Terminal Capacity. 5mm² cables. Order MK Metal-Clad Plus 13A Unswitched Metal Clad Fused Spur with Neon with White Inserts at Screwfix. Everyday products, everyday prices. You made that up. you cannot run spur to spur with sockets incase of over load of cable but. NEW PENFED ONLINE EXPERIENCE. One for the extra sockets, and the other for the batten light. Last Day: Grab DeWalt safety boots and clothing with 10% off at Screwfix. View and enroll in eStatements. Delivery 7 days a week. 2 x 4. However, from a practical point of view you would change the present fcu to an unswitched 13A spur, then connect two 3A fcus one serving each of the boiler and the pump. Buy online & collect in hundreds of stores in as little as 1 minute! Pay your way. Discussion in 'Electricians' Talk' started by Jim, Oct 7, 2004. Screwfix Direct DIY, Paint Supplies: Shop Online at Screwfix Direct Home Improvement for UK Paint Supplies. Buy 13 A Fused Spurs at Screwfix. With RCD. PaulBlackpool, unphased and FatHands like this. . 5mm², 2 x 4mm² or 1 x 6mm² cables. Buy Schneider Electric FCU Fused Spurs at Screwfix. Latched with no need to reset after a loss of power. Flex Outlet. The light switch, again, like the socket, had a FCU installed just before the switch. Click & Collect. Bazza-spark, Sep 15, 2023. 5mm SWA, so need a 5A FCU. I've heard. The ability to track savings goals, budgets, and spending. The reason I asked the original question about the second consumer being fed from a 32 amp RCBO, to a 40 amp 30 mA RCD Consumer Unit, with 2X MCB for lights and sockets. Online, mobile and phone banking are available 24/7. Skip to content. Many. Buy online & collect in hundreds of stores in as little as 1 minute! Thousands of products. I currently have an FCU supplying ONE outside PIR security light. Buy Black FCU Fused Spurs at Screwfix. 5mm2 to junction box, splitting to: 1. Flexible 13A fuse unit. Wood. Not available for delivery. ? thanks for any input / help lads. I turned the switch on and off a few times, there was a bit of a fizzle noise while the spur tried to come on, So I changed the fuse in the spur, although the old fuse had not blown. I’ve also had the top cover trimmed down so it can ‘easily’ be removed (2 screws) if. you cannot run spur to spur with sockets incase of over load of cable but. Aggregate information from multiple sources to get a complete picture of all your financial relationships. 75mm2 flex, and the fcu has a 13A fuse. terrymac Screwfix Select. Discussion in 'Electricians' Talk' started by sparky308, Nov 5, 2005. In Wales the garden is still a special location, so may still need notifying. 1. Supplied with Replaceable 13A Fuse. 5mm cable, this cable is then effectively not suitably protected because clipped direct it only has a rating. Hi all, I've installed an LED floodlight vertically above an FCU switch, and used some 25mm conduit and fittings that I already had. I want to disconnect the existing wiring from the old CU and. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU`s. Order MK Metalclad Plus 13A Switched Metal Clad Fused Spur with White Inserts at Screwfix. comes with a plug, so it can be disconnected. Without RCD. 25Ltr Dry Capacity. com. Power Indicator. Without RCD. Alaska USA operates 67 branches in Alaska, Arizona. Terminal Capacity. Pay your way. Discussion in 'Electricians' Talk' started by Mr I, Feb 8, 2019. Screwfix Community Forum. Home Forums > Screwfix Community Forum > Electricians' Talk > 16mm back box for FCU Discussion in ' Electricians' Talk ' started by torquay123 , Nov 6, 2006 . Cheers mate. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU location on cooker hood install Discussion in ' Electricians' Talk ' started by BodgeTheBuilder , Jun 14, 2020 . Also, if any circuit needed work doing on it, the electrician could have limited access ( depending on the size of the cupboard)seneca Screwfix Select. Flex Outlet. Over 40,000 products. Both the plug and the socket must be changed, do not plug any other item into the socket, or plug the boiler into any other socket as the damage will spread to other plugs and sockets as they will overheat. Prepare the ends of the cable and the cores. Buy Outdoor Fused Spurs at Screwfix. Buy FCU Switches & Sockets at Screwfix. Wood Products. I always put a FCU outside the room and then a flex outlet in the bathroom but the job i refer to was a right pain in the * too so i opted for the easier option. com. Buy FCU Fused Spurs at Screwfix. 3. Buy FCU Fused Spurs at Screwfix. PayPal accepted online. - - - - Call 24/7 on: 03330 112. Delivery 7 days a week The UK’s leading retailer of trade tools and hardware. Is there any reason that this FCU can't be fixed, by a surface mounted box, to the top of the unit instead of cutting a hole in the back of the unit. Without Flex Outlet. Choose “Pay from Outside Account. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. Free returns. Terminal Capacity. Non-Latching Operation. Wellwisher said: ↑. Sliding Wardrobe Doors Track Set. Then I plan on running the cable down to the shed and in the shed wiring it to a garage consumer unit. Print or view a copy of your statement. 99Inc Vat. Credit Human CD changes: 6-11 month 5. com. FREE next day delivery available, free collection in 1 minute. 5% min. Dare say your already aware but by using an FCU you'd be restricted to a total load of 13a across the two double sockets. #13. Terminals accept 3 x 2. I also changed it to the FCU. Below is just a tiny selection of what you'll find at Screwfix Online:fitting a 4pole 32A rotary isolation switch to act as an isolator in a twin and earth wiring single phase 16A circuit leading to an invertor. You could fit a double + single box in place of the double socket. The cable or flex attached to the gas fire is purely to supply the ignition. £13. Log In. I have ordered 50m of 10mm swa cable. Home Forums > Screwfix Community Forum > Electricians' Talk > Cooker conn unit/FCU. FREE next day delivery available, free collection in 1 minute. Having done that, you could fit a 13A fused spur for the immersion heater (hard-wired) with an adjacent 2-gang socket for TV & shower - not spurred from the FCU, but incorporated into the ring by taking one of the existing cables to the immersion spur and the other to the socket - with a short link between the two to maintain the ring -continuity. from a ring circuit it is ok to feed from the ring to the. Delivery 7 days a week Choose from top trade brands. The UK’s leading retailer of trade tools and hardware. Coloumb Screwfix Select. Choose from top trade brands. Buy Flex Outlet FCU Fused Spurs at Screwfix. But if you then inserted a 9th socket somewhere in the ring, all of a sudden it would be OK, even though it is blindingly obvious that the mere. With Flex Outlet. Can't see any point in feeding a 13 amp socket through an fcu! Just use 20 amp dp switches. Triton Thermostatic Mixer Shower Valve 266 x 60 x 50mm, at Screwfix. Raised Slim. Follow the remaining on screen instructions to accept the terms and agreements and. Click & Collect. Home Forums > Screwfix Community Forum > Electricians' Talk > Switch FCU (LED not working) Discussion in 'Electricians' Talk' started by sp383, Nov 13, 2018. #14. Ind spark, Sep 15, 2023. #3. MGW Screwfix Select. Terminals accept 3 x 2. White, moulded safety RCD protected fused connection unit that protects against the risk of a fatal electric shock. Coloumb, Jul 4, 2016 #2. Coloumb Screwfix Select. View all: Masterplug RCD Adaptors. i dont want to cut another hole in the wall and move it along. That way the current to the spur will be shared by the ring conductors, otherwise a single 2. But basically yes you can feed off an FCU as one option. I am wanting to add a double socket in the airing cupboard to charge my electric toothbrush and water pik. You need the neutral to make the light work but you can take a spur from the socket underneath the desk for a light, you could place a FCU next to socket underneath desk then run cable to light switch and then on to light fitting . I now need another socket on the other side of the garage. With RCD. Regards isolation they tell me it’s fine because the kitchen sockets are on an independent circuit on the new MCB so isolated there. 036 cable. com. 10x10 — $90 / year. 2. Now remove both leads on backup battery & remove battery from panel. Stylish Brushed Chrome design with screwless metal front plate and concealed fixing screws. Home Forums > Screwfix Community Forum > Electricians' Talk > Outdoor light with separate pir sensor. Without RCD. It will enter the FCU at the bottom. 75% min$500 12-17 month 5. The UK’s leading retailer of trade tools and hardware. However, from a practical point of view you would change the present fcu to an unswitched 13A spur, then connect two 3A fcus one serving each of the boiler and the pump. Terminal Capacity. Stay tuned for details on our Grand Opening. Over 40,000 products. old menace, Jul 23, 2008. In my opinion it's no different to using 2. Learn More. So the switched FCU will have a spur off the feed side That OK Switches will be labledunphased Screwfix Select For the short lengths involved just use 2. MGW, Nov 6, 2022. To start off the new year with a bang, Navy Federal Credit Union introduced five new credit card bonuses on Tuesday. 13A max. 5 or 2 x 4. Made from durable, high quality urea with antimicrobial properties. 5mm from one of the junction boxes into a FCU which I then fused down to 3 amps and I was then able to power my cctv cameras with a network switch and a. British General 900 Series 13A Unswitched Passive Fused Spur White (8250P) (57) compare. 30mA Active RCD. With Flex Outlet. Screwed Faceplate. #3. A 6amp MCB for the 1 light. The spur is not normally accessible hence the switched FCU. What will you make up next? Don't keep on. FREE next day delivery available, free collection in 1 minute. Optional flex outlet at the base of the front plate provides additional space for larger cables. Discussion in 'Electricians' Talk' started by seneca2, Nov 27, 2007. 2. There is a rule saying one spur can only have a single or double socket or FCU though. Contact PenFed by Phone. All of the lines and rectangles in GREEN are my proposed wiring. Over 40,000 products. I do. Screwfix customers rate this product 4. Hello all, Went to friends last night, 7 month old new build flat. #9. 4m x 1. I know that if on a fcu, you can spur from a spur but I can’t draw more than 13 amps. Say 2 separate 13A double sockets spurred from a single point on the ring with a washing machine, tumble dryer, kettle connected plus the remainder of the load current being drawn on the ring can overheat the connections in the JB or accessory, the cables may be quite. Supplied with four screw cap covers for a sleek profile finish. 2692mm. View all: MK Fused Spurs. #13. Join today and become part of the EFCU family. The FCU is in the middle of the garage (as is the original garage socket it is spurring off) and my new socket powering the LED deck lights is at one end. “. Terminal Capacity. However, saw several FCU's this week all on a ring next to each other then used for towel rails, UF heating etc. Delivery 7 days a week Choose from top trade brands. Can I do any of the following and maintain compliance with the regs? My preferred plan: Connect in an external IP54+ 3A FCU via the (feed or switch?) @ 13A FCU with appropriate cable (1. Without RCD. Check stock, order online & collect in as little as 1 minute. 3. PVC cement had crossed my mind, but not sure if you can apply that over an existing joint. 6amp breaker for the lights and a 16amp breaker for the couple. FREE next day delivery available, free collection in 1 minute. 49 Inc Vat. Buy Switches & Sockets at Screwfix. I also think it looks like part of a RCD, it may connect to the moulded breaker, I remember us having a lot of them in weather proof distribution units, but seem to remember they has a small unit between the two where you can set time delay and leakage current, went up to 1 minute and 5 amp. I'm building some large pantry style cupboards in the space below and wondered if there was any reason using a FCU where the switch used to be to power some LED lights in the cupboard would be a bad. 5mm would not comply with 7671. Ring main feeding FCU with integral RCD, being used to power patio lights and a socket (all outside parts with correct ip rating of course)via 1. The installation was a fcu spurred off of a socket on a radial circuit. There is no need to worry about finding a Heating element with a long flex on it. Account Summary Made Better: Lines of Credit, Payment Due Dates, Current and Available Balances, Certificate Maturity Dates and more showing right from the home screen. 49Inc Vat. With Flex Outlet. Worth mentioning that I've drilled a drain hole in the FCU. Choose from top trade brands. Sliding Wardrobe Doors Track Set. Order MK Metal-Clad Plus 13A Switched Metal Clad Fused Spur & Flex Outlet with White Inserts at Screwfix. Home Tags > fcu. Actually they are all correctly called fused connection units (FCUs). Buy Switched FCU Switches & Sockets at Screwfix. Change the single box to a dual 35mm box. For example, in my kitchen I have 3 switches on a plate feeding the extractor, the main light and the gas hob ignition. adambaz Standard Member. unphased Screwfix Select. See pic for context. 2. Order LAP 13A Switched Fused Spur with Neon White at Screwfix. 2x 2. - - - - Call 24/7 on: 03330 112. The thermal response of a floorslab is much longer than for a radiator system. Screwfix Select. US Toll-Free: 1-800-247-5626. Order MK Metal-Clad Plus 13A Switched Metal Clad Fused Spur & Flex Outlet with White Inserts at Screwfix. 3/5. Free next day delivery available. Assemble with other products into a modular front plate to create a grid. Electrican has done the following, but isn't. Gland the SWA into the junction box and then feed it outside. Terminals accept 3 x 2. Home Forums > Screwfix Community Forum > Electricians' Talk > Outdoor light with separate pir sensor. Ideally I'd like to run a cable from the FCU in one direction with two double sockets daisy chained and another cable in the opposite direction with one double socket. 7/5. . ? this is the kudox box ip44 rated, again in screwfix website shop. FREE next day delivery available, free collection in 1 minute. FREE next day delivery available, free collection in 1 minute. com. Delivery 7 days a week. Requires 35mm Back Box. I’m fairly sure that you’ve misunderstood the reply from Comlec The OP asked about fitting an FCU to power a light fitting from socket Comlec suggested fitting a S (switched) FCU as that saves fitting a separate light switch -. Sign in / Register. consumer unit in shed. . Buy FCU Switches & Sockets at Screwfix. The fittings are each fed by a single 2+e cable which go back to a junction box from which comes, among other things, the 2 gang switch that controls them. 1 A. Which is the correct way to wire kitchen under cabinet lights? a) From the lighting circuit, if so does it need to be independently fused as they're in the kitchen? b) From the kitchen ring main, with an switched FCU spurred on the wall next to a socket? thanks in advance! JP. orgDiscover the benefits of joining Eglin Federal Credit Union, a member-owned, not-for-profit financial cooperative. So do we agree then that an fcu can be fed from a ring in 1. Buy Fixings & Fastenings at Screwfix. That is why the fcu has a 13A fuse. Order online at Screwfix. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. £15. 30 day money back guarantee. Thread by: itisgeorge , Mar 16, 2022 , 6 replies, in forum: Electricians' Talk Cheers. Order Crabtree Capital 13A Switched Fridge Freezer Fused Spur White at Screwfix. Raised Slim Profile. 51 Inc Vat. 4. I have a switch in a closet which controls two floodlights outside. load. For Appliance Protection Circuits. £27. Flexible 13A fuse unit. 2. Screwfix customers rate this product 4. spirits are real 2016 Screwfix Select. To die?to sleep, No more; and by a sleep to say we end The heart-ache and the thousand remarks That flesh is heir to: 'tis a consummationHome Forums > Screwfix Community Forum > Electricians' Talk > Boiler and controller fcu Discussion in ' Electricians' Talk ' started by mrppp , Oct 11, 2016 . 8/5. Bazza Screwfix Select. Hi all, I've installed an LED floodlight vertically above an FCU switch, and used some 25mm conduit and fittings that I already had. sinewave Screwfix Select. Screwfix Community Forum. Masterseal IP56 13A Sw FCU, at Screwfix Direct Masterseal range has been specifically designed for use either outdoors or indoors and in areas heavily exposed to dust and splashing water. If there was a 2-pin socket with RCD protection on the market then it could not have an isolation transformer in it, and therefore would not be allowed in bathrooms. Raised Square. Transfer between multiple deposit accounts & pay loans. Raised Square Profile. One is from the spur going into the FCU and the other going out to the 2gang socket. com. but having a FCU on a spur can cause problems, my dad decided to have a few sockets on a spur, and used a FCU. There is no rule saying you cannot take 2 spurs from the same point on a ring. 4. Log in or Sign up. 4/5. Screwfix Community Forum. No I didn't. Area of bathroom is 2. £3. Free next day delivery available. 5mm T&E in 20mm conduit (1. Search; Your Account Sign in.